APC Metered Rack PDU - Strømfordelingslist (kan monteres i rack) - AC 200/208/230 V - Ethernet 10/100, RS-232 - inngang: NEMA L6-30 - utgangskontakter: 42 (power IEC 60320 C13, IEC 60320 C19) - 0U - svart - for P/N: SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT6KXLTW, SRT8KXLJ

APC Metered Rack PDU - Strømfordelingslist (kan monteres i rack) - AC 200/208/230 V - Ethernet 10/100, RS-232 - inngang: NEMA L6-30 - utgangskontakter: 42 (power IEC 60320 C13, IEC 60320 C19) - 0U - svart - for P/N: SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT6KXLTW, SRT8KXLJ AP8841
Kontakt oss for pris Eks mva
Informasjon
0 På lager
Forventet inn: 07.01.25
APCProdusentAPCUNSPSC
39121017
Artnr
AP8841
 
Antall kontakter42
  • 42 output connectors for extensive device compatibility
  • Operates effectively in temperatures from -5°C to 45°C
  • Circuit breaker for overload protection
  • Remote management via Ethernet 10/100 and RS-232
  • Complies with major safety and environmental standards
Metered rack PDUs provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.

APC by Schneider Electric Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. New AP8000 series Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.

User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, Command Line Interface, or Telnet Interfaces which are complimented by Schneider Electric's StruxureWare solution.

Remote Management Capabilities - Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Local Current Monitoring Display - The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Alarm Thresholds - Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds - Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities.).

Load Indicator LED - Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Flash Upgradeable - Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only).

 